Eattenuation
SCPI Command :
CONFigure:NRSub:MEASurement<Instance>:RFSettings:EATTenuation
- class EattenuationCls[source]
Eattenuation commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- class EattenuationStruct[source]
Response structure. Fields:
Rf_Input_Ext_Att: float: For input path with antenna 1
Rf_Input_Ext_Att_2: float: For input path with antenna 2
- get() EattenuationStruct [source]
# SCPI: CONFigure:NRSub:MEASurement<Instance>:RFSettings:EATTenuation value: EattenuationStruct = driver.configure.nrSubMeas.rfSettings.eattenuation.get()
Defines an external attenuation (or gain, if the value is negative) , to be applied to the input connector. A query returns 1 or 2 values, depending on the number of antennas configured via method RsCMPX_NrFr1Meas.Configure. NrSubMeas.nantenna.
- return:
structure: for return value, see the help for EattenuationStruct structure arguments.
- set(rf_input_ext_att: float, rf_input_ext_att_2: float = None) None [source]
# SCPI: CONFigure:NRSub:MEASurement<Instance>:RFSettings:EATTenuation driver.configure.nrSubMeas.rfSettings.eattenuation.set(rf_input_ext_att = 1.0, rf_input_ext_att_2 = 1.0)
Defines an external attenuation (or gain, if the value is negative) , to be applied to the input connector. A query returns 1 or 2 values, depending on the number of antennas configured via method RsCMPX_NrFr1Meas.Configure. NrSubMeas.nantenna.
- param rf_input_ext_att:
For input path with antenna 1
- param rf_input_ext_att_2:
For input path with antenna 2