Cbgt
SCPI Command :
CONFigure:NRSub:MEASurement<Instance>:SRS:LIMit:PDYNamics:TTOLerance:CBGT
- class CbgtCls[source]
Cbgt commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- class CbgtStruct[source]
Response structure. Fields:
Tt_Power_Less_3_G: float: Tolerance for carrier center frequencies up to 3 GHz.
Tt_Power_Great_3_G: float: Tolerance for carrier center frequencies 3 GHz.
- get() CbgtStruct [source]
# SCPI: CONFigure:NRSub:MEASurement<Instance>:SRS:LIMit:PDYNamics:TTOLerance:CBGT value: CbgtStruct = driver.configure.nrSubMeas.srs.limit.pdynamics.ttolerance.cbgt.get()
Defines test tolerances for power dynamics limits, for channel BW > 40 MHz.
- return:
structure: for return value, see the help for CbgtStruct structure arguments.
- set(tt_power_less_3_g: float, tt_power_great_3_g: float) None [source]
# SCPI: CONFigure:NRSub:MEASurement<Instance>:SRS:LIMit:PDYNamics:TTOLerance:CBGT driver.configure.nrSubMeas.srs.limit.pdynamics.ttolerance.cbgt.set(tt_power_less_3_g = 1.0, tt_power_great_3_g = 1.0)
Defines test tolerances for power dynamics limits, for channel BW > 40 MHz.
- param tt_power_less_3_g:
Tolerance for carrier center frequencies up to 3 GHz.
- param tt_power_great_3_g:
Tolerance for carrier center frequencies 3 GHz.