Cblt

SCPI Command :

CONFigure:NRSub:MEASurement<Instance>:SRS:LIMit:PDYNamics:TTOLerance:CBLT
Commands in total: 1
Subgroups: 0
Direct child commands: 1
class CbltStruct[source]

Response structure. Fields:

  • 1 Tt_Power_Less_3_G: float: Tolerance for carrier center frequencies up to 3 GHz.

  • 2 Tt_Power_Great_3_G: float: Tolerance for carrier center frequencies 3 GHz.

get() CbltStruct[source]
# CONFigure:NRSub:MEASurement<Instance>:SRS:LIMit:PDYNamics:TTOLerance:CBLT
value: CbltStruct = driver.configure.nrSubMeas.srs.limit.pdynamics.ttolerance.cblt.get()

Defines test tolerances for power dynamics limits, for channel BW up to 40 MHz.

Returns:

structure: for return value, see the help for CbltStruct structure arguments.

set(tt_power_less_3_g: float, tt_power_great_3_g: float) None[source]
# CONFigure:NRSub:MEASurement<Instance>:SRS:LIMit:PDYNamics:TTOLerance:CBLT
driver.configure.nrSubMeas.srs.limit.pdynamics.ttolerance.cblt.set(tt_power_less_3_g = 1.0, tt_power_great_3_g = 1.0)

Defines test tolerances for power dynamics limits, for channel BW up to 40 MHz.

Parameters:
  • tt_power_less_3_g – Tolerance for carrier center frequencies up to 3 GHz.

  • tt_power_great_3_g – Tolerance for carrier center frequencies 3 GHz.